Clean Rooms
A clean Room is a controlled environment where pollutants like dust, airborne microbes, and aerosol particles are filtered out in order to provide the cleanest area possible.
Health Care Clean Rooms
Protect patients and processes with a turn-key solution for:
. Operation Theater
. IP pharmacy
. Chemotherapy pharmacy
. TPN Room
. IV preparation room
. Critical ICU rooms
. IVF preparation room
. CSSD
Pharmaceutical Facilities
Pharmaceutical manufacturing requires a high level of cleanliness and sterile environments for production.
We provide solutions to achieve successful cleanliness on:
. From ISO5 to ISO8
. HVAC
. Paneling System
. SS Furniture
. Isolators
. Production Equipment
Laboratories
Maintain effective contamination control with our turn-key solutions for:
. Testing Laboratories
. Academic Laboratories
. Quality and Production testing Labs
​
​
​
​
​
Manufacturing Facilities
Protect the manufactured product by applying our high-standard solutions to your facility:
. Food Industry
. Packing and Seal
. Electronics
. Weapons
​
​
​
​
Walls and Ceiling Panels
. Skin: PCGI PCGI, SS/SS or HPL
. Structural frame work: GI
. Thickness of Sheet: 0.6 0.8 mm
. Thickness of Powder Coating: 60 80 microns, Thickness of Pre coating: 30 35 microns
. Insulation: PUF density 40.2 kg/m 3 PIR density 48.2 kg/m 3 or ROCKWOOL density 96 kg/m 3 144 kg/m 3
. Sealant: Food-grade silicon on both sides of the panels. Gap should not be more than 4 mm
. Dimensions: Width 1185 mm 900 mm/ 585 mm/ 385 mm standard size to place in layout - Height As per Layout
. Panel thickness: 35 50 75 80 100 150 mm
. Support: Powder coated Base runners with self-supported panels with interconnecting profile
. Color: RAL 9001 9002 9003 std color any other color can be provided from RAL chart
. Panel type: Progressive or Non progressive
​
​
​
View Panels
- Technical description: Supply and Installation of double glass 6 mm thick view panel flush from
both sides of the wall, and fixed on both sides with adhesive tape over GI frame width to match the wall thickness with silica gel desiccant arrangement and made airtight with sealant
- Material of construction: Extruded aluminum profiles Powder coated GI
- Dimension: View Panel Glass Size Depends on the size of each view panel
- Glass thickness type: Plain Toughened 6 mm thk
- Itching: 20 mm black border ceramic paint
- Tape: EPDM Gasket with one side adhesive or 3M tape
. Silicon: All four sides will be filled with sealants to maintain uniformity
. Desiccant material: Silica gel provided inside the provide to absorb moisture
. Type: Single glass/Both side glass, Break open panels, Civil windows full glass panels
​
Doors
- Technical description: Supply and Installation of double glass 6 mm thick view panel flush from
both sides of the wall, and fixed on both sides with adhesive tape over GI frame width to match the wall thickness with silica gel desiccant arrangement and made airtight with sealant
- Material of construction: Extruded aluminum profiles Powder coated GI
- Dimension: View Panel Glass Size Depends on the size of each view panel
- Glass thickness type: Plain Toughened 6 mm thk
- Itching: 20 mm black border ceramic paint
- Tape: EPDM Gasket with one side adhesive or 3M tape
. Silicon: All four sides will be filled with sealants to maintain uniformity
. Desiccant material: Silica gel provided inside the provide to absorb moisture
. Type: Single glass/Both side glass, Break open panels, Civil windows full glass panels
​
Pass Boxes
Dynamic and Passive Pass boxes are usually used in transfers between different Classified Rooms.
There are two types of Pass boxes – wall Mounted (Where Material Sizes Are Small ,E.g- Sachet ,Pouch etc ) another is Floor Mounted (When there is Trolley Movement)
MOC – SS 304 /316
​
​
​
​
​
​
​
​
​
​
​
​
​
​
Laminar Air Flow - Ceiling or Stand
Vertical Laminar Flow units are used to achieve cleanliness Level ISO-5 in the Work Station and Prevent Product contamination.
It can be Suspended from the Ceiling / Mounted on Stand, Depending on the User Requirement.
​
​
​
Sampling / Dispensing Booth
Downward Forced air sampling booth extracts at a low level into the booth's filtration system where contaminated particles recirculate into the booth Air Flow.
In standard Working conditions, the Pharmaceutical dispensing booth air is pulled through the main chamber to steel exhaust grills, used to fasten the HEPA & PRE-filters fitted in the rear side of the unit. It suppresses airborne dust particles away from the users breathing area.
​
Biosafety Cabinets
A biosafety cabinet (BSC)—also called a biological safety cabinet or microbiological safety cabinet—is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level.
Several different types of BSC exist, differentiated by the degree of bio-containment required.
​
​
Dedusting Booth
Arrest dust at the source with De-dusting Tunnel. Reduce dust levels, improve product quality and yield.
Our De-dusting Tunnels remove loose particles and dust that accumulate on raw material containers including drums, cartons, and bags prior to sampling. Particles are collected in a tray, and the filtration system picks up airborne particulates.
21CFR and GMP compliant, automated, mechanized system. Delivers consistent performance.
​
Air Shower
Air Showers are self contained chambers installed at entrances to cleanrooms and other controlled environments. They minimize particulate matter entering or exiting the clean space.
Personnel and materials entering or exiting the controlled environment are “scrubbed” by high-velocity HEPA-filtered air jets with velocities of 20-22m/s (4000-4300fpm).
Contaminated air is then drawn through the base within the unit, filtered, and recirculated. This unit can be Served in industries of micro-electronics, semiconductors, pharmaceutical, spray painting, laboratory animal research and food market
Dynamic Garment Storage Cabinet
Cleanroom garments can accumulate contamination during storage and between laundry washes, which in turn may lead to lower product yields and increased product quality issues.
The enhanced filtration system on the garment storage cabinet is designed to provide the highest level of air quality within the work zone, meeting all relevant standards.
​
​
​
​
​
Isolators
Isolators provide a working space that is detached from the surrounding environment. Hence, manipulation can be executed within space from the outside without the integrity being compromised.
Pressure regime:
. Positive or negative with respect to ambient
. Differential decay within the chamber
Cleanliness level and environment control:
. Cleanliness level as defined in ISO standard with Temp and Rh control
​
Inspection Machine- Vials and Ampoules
Vial and ampoule inspection machines are a promising means to ensure production process control and safety in general.
Pharmaceutical companies install Vial & Ampoule inspection machines for visual inspection, leak detection, and discovery of foreign particles in pharmaceutical containers.
Advancement in technology also impacts patient consumer expectations regarding standards of hygiene, and Vial & Ampoule inspection machines are critical to ensuring the same.
​
​